| Parameter / Equipment | Range |
|---|---|
| DC Voltage – Generate High Voltage |
(0 to 329.9999) mV (0.33 to 3.299999) V (3.3 to 32.99999) V (33 to 329.9999) V (330 to 1000.000) V (1 to 5) kV dc (5 to 9) kV pulse (>9 to 40) kV pulse |
| DC Voltage – Measure | (0 to 100) mV (0 to 1) V (0 to 10) V (0 to 100) V (0 to 1000) V (0 to 200) mV (0 to 2) V (0 to 20) V (0 to 200) V (0 to 1000) V |
| DC Current – Generate | (0 to 329.999) µA (0.33 to 3.29999) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.33 to 2.99999) A (3.5 to 10) A (>10 to 19) A |
| DC Current – Measure, Fixed Points | (0 to 100) μA (0 to 1) mA (0 to 10) mA (0 to 100) mA (0 to 400) mA (0 to 1) A (0 to 3) A (0 to 10) A (0 to 200) μA (0 to 2) mA (0 to 20) mA (0 to 200) mA (0 to 2) A (0 to 20) A |
| Resistance – Generate | (0 to 32.9999) Ω (33 to 329.9999) Ω 330 Ωto 3.29999 kΩ (3.3 to 32.9999) kΩ (33 to 329.9999) kΩ 330 kΩto 3.299999 MΩ (3.3 to 32.99999) MΩ (33 to 100.0000) MΩ |
| Fixed Points | 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ (0.1 to 1) Ω (1 to 10) Ω (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ |
| Resistance – Measure | (0 to 10) Ω (0 to 100) Ω (0 to 1) kΩ (0 to 10) kΩ (0 to 100) kΩ (0 to 1) MΩ (0 to 10) MΩ (0 to 100) MΩ (0 to 2) Ω (0 to 20) Ω (0 to 200) Ω (0 to 2) kΩ (0 to 20) kΩ (0 to 200) kΩ (0 to 2) MΩ (0 to 20) MΩ (0 to 200) MΩ (0 to 2) GΩ |
| AC Voltage – Generate (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.29999) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V |
45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 10 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz |
| AC Voltage – Measaure (0 to 100) mV (0 to 1) V (0 to 10) V (0 to 100) V (0 to 1000) V (0 to 200) mV (0 to 2) V (0 to 20) V (0 to 200) V (0 to 1000) V |
10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz |
| AC Current – Generate (29.00 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.09999) A (1.1 to 10.9999) A (11 to 20.5) A |
45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz 45 Hz to 1 kHz (45 to 100) Hz (45 to 100) Hz |
| AC Current – Measure 100 µA 1 mA (0 to 10) mA (0 to 100) mA (0 to 400) mA (0 to 1) A (0 to 3) A (0 to 10) A (0 to 200) µA (0 to 2) mA (0 to 20) mA (0 to 200) mA (0 to 2) A (0 to 20) A |
10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 1 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 1 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz 10 Hz to 5 kHz |
| Electrical Calibration of Thermocouples – Generate and Measure Type B Type E Type J Type K Type N Type R Type S Type T |
(600 to 800) ºC (>800 to 1000) ºC (>1000 to 1550) ºC (>1550 to 1820) ºC (-250 to -100) ºC (>-100 to -25) ºC (>-25 to 350) ºC (>350 to 650) ºC (>650 to 1000) ºC (-210 to -100) ºC (>-100 to -30) ºC (>-30 to 150) ºC (>150 to 760) ºC (760 to 1200) ºC (-200 to -100) ºC (>-100 to -25) ºC (>-25 to 120) ºC (>120 to 1000) ºC (>1000 to 1372) ºC (-200 to -100) ºC (>-100 to -25) ºC (>-25 to 120) ºC (>120 to 410) ºC (>410 to 1300) ºC (0 to 250) ºC (>250 to 400) ºC (>400 to 1000) ºC (>1000 to 1767) ºC (0 to 250) ºC (>250 to 1000) ºC (1000 to 1400) ºC (1400 to 1767) ºC (-250 to -150) ºC (>-150 to 0) ºC (0 to 120) ºC (120 to 400) ºC |
| Electrical Calibration of Thermocouples – Measure3 Type J Type K Type T Type E Type R Type S Type B Type N |
(-200 to 0) ºC (>0 to 200) ºC (>200 to 1100) ºC (-190 to 0) ºC (>0 to 1300) ºC (-200 to 0) ºC (>0 to 390) ºC (-200 to 0) ºC (>0 to 990) ºC (>0 to 100) ºC (>100 to 1500) ºC (>0 to 1500) ºC (>1500 to 1700) ºC (600 to 1800) ºC (-190 to 0) ºC (>0 to 1200) ºC |
| Electrical Calibration of Thermocouples – Generate3 Type J Type K Type T Type E Type R Type S Type B Type N |
(-150 to 0) ºC (>0 to 500) ºC (>500 to 1100) ºC (-190 to 0) ºC (>0 to 1350) ºC (-200 to 0) ºC (>0 to 380) ºC (-200 to 0) ºC (>0 to 980) ºC (>0 to 1700) ºC (>0 to 1700) ºC (600 to 1800) ºC (-190 to 0) ºC (>0 to 1280) ºC |
| Electrical Calibration of RTD – Generate Pt 385, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω |
(-200 to -80) ºC (-80 to 0) ºC (>0 to 100) ºC (>100 to 300) ºC (>300 to 400) ºC (>400 to 630) ºC (>630 to 800) ºC (-200 to -80) ºC (>-80 to 0) ºC (>0 to 100) ºC (>100 to 260) ºC (>260 to 300) ºC (>300 to 400) ºC (>400 to 600) ºC (>600 to 630) ºC (-200 to -80) ºC (>-80 to 0) ºC (>0 to 100) ºC (>100 to 260) ºC (>260 to 300) ºC (>300 to 400) ºC (>400 to 600) ºC (>600 to 630) ºC (-200 to -80) ºC (>-80 to 0) ºC (0 to 100) ºC (>100 to 260) ºC |
| Electrical Calibration of RTD- Measure Pt 385, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Pt 385, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω |
(-180 to 0) ºC (>0 to 550) ºC (-180 to 100) ºC (>100 to 500) ºC < 0 ºC (0 to550) ºC (-180 to 0) ºC (>-100 to 550) ºC (-190 to 0) ºC (>0 to 780) ºC (-190 to 0) ºC (>0 to 620) ºC (-190 to 0) ºC (>0 to 620) ºC (-190 to 0) ºC (>0 to 620) ºC |